Artificial Intelligence has become a cornerstone technology enabling companies to accelerate growth and gain a competitive advantage. High-performance computing systems have become a necessity for faster output. But the resulting workload is causing bottlenecks not in code generation, but in cooling.

With AI and cloud computing driving data center demand of CAGR of up to 14%, cooling systems have become critical for maintaining server operation stability and preventing costly downtime.

Companies are increasingly adopting tailored cooling systems, particularly as AI workloads drive higher rack densities and thermal loads. These customised solutions align cooling capacity with IT requirements.

In the following sections, we explore the importance of cooling in data centers and how plant engineering can help improve cooling system efficiency and performance.

Why do Data Centers need Cooling?

AI workloads are causing data centers to work overtime, increasing heat and energy consumption. An average data center covers 100,000 sq. ft. of a facility, while hyperscale data centers (primarily used for cloud services and AI workloads) can span as much as 10 million.

An overheated data center can cause:

  • Power fluctuations
  • Hardware malfunctions
  • System crashes
  • Slower computing

This type of large-scale and high-density computing requires an efficient cooling system.

Cooling systems maintain an ambient temperature within the data centers and prevent IT equipment malfunctions.

Here are some of the cooling options currently used by data centers:

Air Cooling

It is the most common method used to cool IT infrastructure. Cooling fans circulate hot and cold air between aisles of racks, but the fans themselves generate more heat and can cause noise disruptions.

These are the main air cooling systems found in data centers:

  • Air conditioners
  • Air Handler Units
  • Free cooling
  • Evaporative cooling

Liquid Cooling

Direct-to-Chip Cooling

Direct-to-Chip cooling tackles the heat source. A Coolant Distribution Unit (CDU) supplies cooled liquid to the racks, where cold plates directly absorb heat from the chips. The heated liquid is then returned to the CDU, where it is cooled and recirculated. It is most suitable for managing AI workloads.

Immersion Cooling

The server racks are immersed in dielectric fluids, allowing heat to be absorbed directly from the equipment. The fluids are non-conductive, keep the servers safe and reduce energy consumption.

How are AI workloads changing Data Center Cooling requirements?

Data centers rely on efficient cooling to run heavy AI computing workloads, as rack densities are pushed higher; choosing between air, liquid, and hybrid cooling is critical to keep data centers continuously operable.

Data centers operate on an intricate network of chips housed in racks, arranged in rows and columns within secure facilities. The components need to operate at an optimum capacity at all times to ensure signals and data are processed rapidly at a pace businesses rely on.

Maintaining optimal temperature is critical to sustain this performance, making cooling systems essential.

Hybrid Cooling (Air Cooling + Liquid Cooling)

The climate in data centres running AI computing may not always remain the same. Potential thermal shutdowns and increasing power densities are real safety hazards that could compromise the physical climate of data centers.

Instead of relying entirely on air cooling or water cooling, a mixture of both ensures high-density AI data centers maintain an optimum temperature level for continuous operations.

How does hybrid cooling work?

It combines direct-to-chip liquid cooling and air cooling to minimise heat generation in high-powered data centers operating AI workloads.

Design

A properly designed layout accounts for rack aisle arrangement and separates hot and cold air streams inside the data centers.

Containment

Using containment, where the racks act as physical barriers, the cooling system supplies cold air to the front of the server racks, while the hot exhaust air is collected from the rear of the racks.

Liquid Cooling

The GPUs installed within the servers can be cooled using direct-to-chip liquid cooling, removing heat directly from the GPU and transferring it to a liquid coolant. The coolant is then recirculated through a coolant distribution unit (CDU), where the heat is transferred to the facility cooling system.

Air Cooling

The other components, such as memory, Network Interface Cards (NICs), and Power Supply Units (PSUs), expel heat into the surrounding air, which is removed using air cooling and directed toward the hot aisle.

What are the costs of inadequate AI data center cooling?

When data centers operate outside the recommended temperature range, the resulting heat generation can cascade quickly into hardware throttling or failures, excessive energy consumption, and shortening equipment life, driving up total ownership costs.

Electricity Consumption

Inefficient cooling systems can lead to energy wastage. Inadequate hot and cold airflow can cause IT equipment to operate at higher temperatures, wasting 30-40% of the data center facility’s energy.

Maintenance Expenses

Increasing heat inside data centers can accelerate equipment damage leading to higher repair and maintenance costs.

Hardware Degradation

Exposure to extreme heat due to inadequate temperature control in data centers can cause wire fraying, battery swelling, and bent circuit boards. The excess heat causes increased chemical reactions, reducing the lifespan of equipment

Retrofitting

Upgrading outdated, space-constricted data centers to support AI computing can cost millions, particularly when accommodating liquid cooling systems.

How is Data Center Cooling infrastructure designed using plant and piping engineering?

Plant and piping engineering helps create a structured routing path for coolant liquids and fluids associated with keeping data centers at an optimum temperature.

A cooling infrastructure should be engineered to support the transportation and distribution of water and other chemical fluids.

Plant and piping engineering plays a critical role in routing these fluids through the data center and ensuring consistent cooling.

An optimally planned and designed data center cooling system considers the following:

  • Potential heat load generated
  • Aims to optimise energy consumption
  • Minimises plumbing and maintenance costs

Here are some of the ways plant and piping design contributes to efficient data center cooling:

Consistent Flow and Operations

Data centers need to be operable 24/7 to ensure AI workloads are processed without interruptions.

Piping systems are essential for transferring hot and cold fluids across server racks. Backup pumping and VFD (Variable Frequency Drive) that immediately adjusts flow rate and pressure based on temperature in the data center ensure consistent flow for optimal cooling.

  • Selecting appropriate pipe sizing for carrying required coolant flow
  • Securing the piping network with alternate pipe paths, pumps, valves and cooling equipment in case of pipe failure.

Minimise Equipment Damage

For liquid cooling, coolant is delivered to the server racks directly, increasing the risk of fluids converting into moisture or component temperatures falling below dew point.

Efficient pipe routing and temperature control minimise the risk of condensation and protect the equipment from water damage.

  • Pipe routing through dedicated corridors, ceilings, or plant rooms
  • Insulated piping to prevent pipe surface from becoming colder than dew point

Prevent Corrosion

Closed-loop piping design ensures that water and fluids are contained within the piping system, preventing exposure to debris and contaminants.

The technology cooling system loop circulates cooling fluid towards the IT equipment, while the facility water system loop serves the cooling infrastructure and heat-rejection systems (dry cooler, cooling tower, cooling plant). Fluid circuits are hydraulically separated through these loops to prevent corrosion risk.

  • Selecting non-conductive pipe materials to prevent electrical reactions from pipes rubbing against each other
  • Resizing pipes for smoother fluid flow between broader and narrower loop transitions instead of sharp 90-degree elbows or blunt step downs

Leak Detection

Unexpected water pipeline failure can damage sensitive hardware. Maintenance and repairs can cause shutdowns, AI workloads to accumulate and strain the data center’s operating capability.

Piping network layouts are designed to avoid having pipes directly above the equipment. Embedding sensors in pipe joints is another way to detect leaks before they turn into major pipe failures.

  • Connecting specific pipe sections to automated valves will arrest leaks and prevent them from reaching the rest of the piping network.
  • Flow meters monitor pressure drops and flow imbalance, helping identify minor cracks before they become leaks.

Future Expansions

Data centers evolve continuously to accommodate increasing AI workloads. However, this also increases the need for expansion in the piping system for additional fluid flow for cooling systems.

Hydraulic models help prepare for changing fluid dynamics and simulate the flow towards server racks. Expansion joints to existing piping networks help redirect loads, vibration and thermal expansion due to increased cooling requirements.

  • Modular skids can help connect additional pumps and valves to the existing system
  • Main pipe headers can be sized to accommodate future flow with connection points reserved for additional cooling loops

Partner with expert Plant and Piping Engineers for Data Center Cooling Design

Cooling technology is an investment choice that serves companies in the long run, saving costs and repair time.

At Sedin Engineering, we combine your data center cooling requirements with our plant and piping design engineering services to build robust, reliable piping systems. Our solutions are thoughtfully crafted to support your current needs while providing the scalability and flexibility required for future business growth.

Need a custom-designed cooling solution for your data center? Contact us today.